• HOME
  • About Us
  • CONTACT US
PT. BANDAR ANEKA TEKNIK INDONESIA - adalah perusahaan penyedia electrical dan automation part, kami adalah importir langsung dar eropa, america, asia.
  • MERCOTAC  
    • One Conductor
    • Two Conductors
    • Three Conductors
    • Four Conductors
    • Six Conductors
    • Eight Conductors
  • PILZ  
    • Sensor Technology  
      • Position monitoring devices
      • Safety switches
    • Relay Modules
    • Small Controllers PNOZmulti
    • Controllers
    • Drive Technology
    • Industrial Networks
    • Operation and monitoring
  • OMRON  
    • Sensors  
      • Fiber units
      • Fiber Amplifier
      • Sensor communications units
      • Photoelectric Sensors  
        • Separate Amplifier
        • Built-in Amplifier
    • Input and Output (I/O)
    • Industrial PC  
      • NYP
      • NYB
      • NYE
      • NY5
      • NYM
    • Human Mechine Interfaces (HMI)  
      • NA series
      • NB series
    • PLC  
      • CJ2
      • CP2E
      • CP1L
      • CP1E
      • CP1H
  • IFM  
    • Sensors  
      • All inductive sensors
  • SIEMENS
  • BAUMER  
    • Object Detection
    • Distance Measurement
    • Sensors
  • BALLUFF  
    • Sensors
    • RFID
    • Machine vision and optical
    • Identification
    • Industrial Network
    • Connectivity
    • Power Supplies
    • Human Machine Interface
    • Human Machine Interface
    • Safety
    • Accessories
  • CARLO GAVAZZI  
    • Sensors
    • Switch
    • Control
  • DELTA  
    • Inductor
    • Transformer
    • Delta DVP SLIM PLC EXTN
    • VFD-CP2000
    • VFD-E
    • VFD-EL
    • VFD-EL-W
    • VFD-ME
    • VFD-MS300
    • Delta HMI DOP-100 series
    • Delta HMI TP04 series
    • Delta PLC AS PLC-EXTN series
    • Delta PLC DVP ES2/ES2 series
    • Delta PLC DVP-SE series
    • Delta PLC DVP-SS2 series
    • Delta Power Supply
    • Delta servo drive ASDA-A2 series
    • Delta servo motor ECMA- series
    • frequency converter
  • MITSUBISHI  
    • Inverters
    • AC Servos
    • MELSEC iQ-F Series
    • MELSEC iQ-R Series
    • MELSEC-F Series
    • MELSEC-L Series
    • MELSEC-Q Series
  • SICK  
    • Photoelectric Sensors
  • KEYENCE
  • ABB  
    • ACS510 Drives
    • ACS580 Drives
    • Frequency converters
    • HMI
    • Options
    • plc
    • Soft starter
    • UPS power supply
    • Lain - Lain
  • ALLEN BRADLEY  
    • AB servo feed back line Price List
    • Cable Price List
    • CompactLogix Price List
    • MicroLogix Price List
    • MPL Low inertia servomotor Price List
    • PanelView HMI Price List
    • POINT I/O,FLEX I/O Price List
    • PowerFlex Drive Price List
    • Servo Motor Price List
    • TL and TLY compact service Price List
    • VP Series Service Motor Price List
    • VPL Series Service Motor Price List
    • Produk Lainnya
  • MIDORI PRECISIONS
  • BTSR  
    • CONSTANT TENSIONS FEEDERS BTSR
    • PC links Software Solutions BTSR
  • LEUZE
  • BECKHOFF
  • LENZE
  • WENGLOR
  • PHOENIX CONTACT
  • B&R
  • MURR Elektronik
  • Air TAC  
    • Air TAC Air source handling element
    • Air TAC Cylinder Price List
    • Air TAC Joint Price List
    • Air TAC Pneumatic control valve Price List
    • Air TAC Trachea Price List
    • Cylinders Price List
    • Fittings Price List
    • Hydraulic Shock Absorbe Price List
    • Precision slide cylinder Price List
    • Slide Table Cylinders Price List
    • AIRTAC
  • AUTONICS  
    • Autonics Photoelectric switches
    • Autonics Proximity switches
    • Autonics Temperature controller
  • BECKHOFF  
    • Digital output terminal module KL
    • Industrial control / CX
    • plug-in modules
  • BENTLY NEVADA  
    • Extension cables
    • PLC, detection module
    • Pre-extender
    • Vibration probes/Eddy-current sensors
  • Bosch TOOL
  • DANFOSS  
    • Danfoss low - voltage inverter iC2 - Micro
  • EATON  
    • Eaton Fuse
    • Ups Power Supply
  • FESTO  
    • Festo Compact cylinder
    • Festo Compact cylinder ADN-S
    • Festo cylinder DSBC Price List
    • Festo Push-in fitting QS Price List
  • FINDER  
    • Series 55 - Miniature Power Relays 12
    • Series 56 - Miniature Power Relays 12 A
  • HARTING  
    • Connector
    • Connector
  • IDEC  
    • SWITCH BUTTONS
  • KEYENCE  
    • Barcode Scanners
    • Fiber Optic Sensors
    • Handheld Scanners
    • Photoelectric Sensors
    • Vision Sensors
    • Vision Systems
  • KINCO  
    • Frequency Transformer
    • HMI
    • PLC
  • MEANWELL  
    • Charger / Adapter
    • Chassis-mounted power supply and baseplate-mounted power supply
    • DIN rail type power supply
    • LED power supply
    • LED power supply charger
    • Price list for Enclosure-mounted / DIN Rail-mounted / Substrate-mounted
    • Substrate type / Chassis type / LED power supply
  • PANASONIC  
    • COMPONENTS & DEVICES  
      • RELAYS / COUPLERS  
        • PhotoMOS
        • Solid State Relays
        • PhotoIC Coupler
        • Power Relays (Over 2A)
        • High-capacity DC Cutoff Relays
        • Signal Relays (2A or less)
        • MIcrowave Devices
        • Safety Relays
        • Interface Terminal
        • Automotive Relays
    • Sensors
    • ENCODERS/POTENTIOMETERS  
      • ENCODERS
      • ENCODERS
      • ROTARY POTENTIOMETERS
      • POSITION SENSOR
    • COOLING FAN  
      • AXIAL TYPE
      • RADIAR TYPE
    • FA SENSORS & COMPONENTS  
      • GENERAL-PURPOSE SENSORS
      • MEASUREMENT SENSORS  
        • LASER DISPLACEMENT SENSOR
      • MOTORS FOR FA  
        • MINAS A7 FAMILY
        • MINAS A6 FAMILY
      • PROGRAMMABLE CONTROLLERS  
        • PROGRAMMABLE CONTROLLERS
      • HUMAN MACHINE INTERFACE
      • GENERAL-PURPOSE SENSORS  
        • Photoelectric Sensors
        • LASER SENSORS
        • MICRO PHOTOELECTRIC SENSORS
        • AREA SENSORS
        • PRESSURE SENSORS
        • INDUCTIVE PROXIMITY SENSORS
        • PARTICULAR USE SENSORS
        • SENSOR OPTIONS
  • AECO
  • SAKAE   
    • CONTACT TYPE
    • CONTACLESS TYPE
    • OIL FILLED TYPE
    • MULTI-TURN POTENTIOMETERS  
      • CONTACT TYPE
      • Contactless type
      • Oil-Filled type
    • LINEAR-MOTION POT  
      • CONTACT TYPE
      • CONTACLESS TYPE
      • OIL FILLED TYPE
      • RESISTIVE ELEMENT SUB-ASSEMBLY
    • SEESAW-MOTION POTENTIOMETERS UNIT
    • TURNS-COUNTING DIAL
    • JOYSTICK CONTROLLERS
  • Produk Lainnya
  • ASCO
  • azbil
  • BANNER
  • NIDEC  
    • Pressure Sensor Modules
    • Potentiometers, Inclinometers
    • Rotary Encoders
  • BURKERT  
    • Solenoid Valves  
      • General Purpose 2/2 Solenoids
  • HOME
  • About Us
  • CONTACT US
  • Home
  • ABB
  • Soft starter

Categories

  • MERCOTAC
    • One Conductor
    • Two Conductors
    • Three Conductors
    • Four Conductors
    • Six Conductors
    • Eight Conductors
  • PILZ
    • Sensor Technology
      • Position monitoring devices
      • Safety switches
    • Relay Modules
    • Small Controllers PNOZmulti
    • Controllers
    • Drive Technology
    • Industrial Networks
    • Operation and monitoring
  • OMRON
    • Sensors
      • Fiber units
      • Fiber Amplifier
      • Sensor communications units
      • Photoelectric Sensors
        • Separate Amplifier
        • Built-in Amplifier
    • Input and Output (I/O)
    • Industrial PC
      • NYP
      • NYB
      • NYE
      • NY5
      • NYM
    • Human Mechine Interfaces (HMI)
      • NA series
      • NB series
    • PLC
      • CJ2
      • CP2E
      • CP1L
      • CP1E
      • CP1H
  • IFM
    • Sensors
      • All inductive sensors
  • SIEMENS
  • BAUMER
    • Object Detection
    • Distance Measurement
    • Sensors
  • BALLUFF
    • Sensors
    • RFID
    • Machine vision and optical
    • Identification
    • Industrial Network
    • Connectivity
    • Power Supplies
    • Human Machine Interface
    • Human Machine Interface
    • Safety
    • Accessories
  • CARLO GAVAZZI
    • Sensors
    • Switch
    • Control
  • DELTA
    • Inductor
    • Transformer
    • Delta DVP SLIM PLC EXTN
    • VFD-CP2000
    • VFD-E
    • VFD-EL
    • VFD-EL-W
    • VFD-ME
    • VFD-MS300
    • Delta HMI DOP-100 series
    • Delta HMI TP04 series
    • Delta PLC AS PLC-EXTN series
    • Delta PLC DVP ES2/ES2 series
    • Delta PLC DVP-SE series
    • Delta PLC DVP-SS2 series
    • Delta Power Supply
    • Delta servo drive ASDA-A2 series
    • Delta servo motor ECMA- series
    • frequency converter
  • MITSUBISHI
    • Inverters
    • AC Servos
    • MELSEC iQ-F Series
    • MELSEC iQ-R Series
    • MELSEC-F Series
    • MELSEC-L Series
    • MELSEC-Q Series
  • SICK
    • Photoelectric Sensors
  • KEYENCE
  • ABB
    • ACS510 Drives
    • ACS580 Drives
    • Frequency converters
    • HMI
    • Options
    • plc
    • Soft starter
    • UPS power supply
    • Lain - Lain
  • ALLEN BRADLEY
    • AB servo feed back line Price List
    • Cable Price List
    • CompactLogix Price List
    • MicroLogix Price List
    • MPL Low inertia servomotor Price List
    • PanelView HMI Price List
    • POINT I/O,FLEX I/O Price List
    • PowerFlex Drive Price List
    • Servo Motor Price List
    • TL and TLY compact service Price List
    • VP Series Service Motor Price List
    • VPL Series Service Motor Price List
    • Produk Lainnya
  • MIDORI PRECISIONS
  • BTSR
    • CONSTANT TENSIONS FEEDERS BTSR
    • PC links Software Solutions BTSR
  • LEUZE
  • BECKHOFF
  • LENZE
  • WENGLOR
  • PHOENIX CONTACT
  • B&R
  • MURR Elektronik
  • Air TAC
    • Air TAC Air source handling element
    • Air TAC Cylinder Price List
    • Air TAC Joint Price List
    • Air TAC Pneumatic control valve Price List
    • Air TAC Trachea Price List
    • Cylinders Price List
    • Fittings Price List
    • Hydraulic Shock Absorbe Price List
    • Precision slide cylinder Price List
    • Slide Table Cylinders Price List
    • AIRTAC
  • AUTONICS
    • Autonics Photoelectric switches
    • Autonics Proximity switches
    • Autonics Temperature controller
  • BECKHOFF
    • Digital output terminal module KL
    • Industrial control / CX
    • plug-in modules
  • BENTLY NEVADA
    • Extension cables
    • PLC, detection module
    • Pre-extender
    • Vibration probes/Eddy-current sensors
  • Bosch TOOL
  • DANFOSS
    • Danfoss low - voltage inverter iC2 - Micro
  • EATON
    • Eaton Fuse
    • Ups Power Supply
  • FESTO
    • Festo Compact cylinder
    • Festo Compact cylinder ADN-S
    • Festo cylinder DSBC Price List
    • Festo Push-in fitting QS Price List
  • FINDER
    • Series 55 - Miniature Power Relays 12
    • Series 56 - Miniature Power Relays 12 A
  • HARTING
    • Connector
    • Connector
  • IDEC
    • SWITCH BUTTONS
  • KEYENCE
    • Barcode Scanners
    • Fiber Optic Sensors
    • Handheld Scanners
    • Photoelectric Sensors
    • Vision Sensors
    • Vision Systems
  • KINCO
    • Frequency Transformer
    • HMI
    • PLC
  • MEANWELL
    • Charger / Adapter
    • Chassis-mounted power supply and baseplate-mounted power supply
    • DIN rail type power supply
    • LED power supply
    • LED power supply charger
    • Price list for Enclosure-mounted / DIN Rail-mounted / Substrate-mounted
    • Substrate type / Chassis type / LED power supply
  • PANASONIC
    • COMPONENTS & DEVICES
      • RELAYS / COUPLERS
        • PhotoMOS
        • Solid State Relays
        • PhotoIC Coupler
        • Power Relays (Over 2A)
        • High-capacity DC Cutoff Relays
        • Signal Relays (2A or less)
        • MIcrowave Devices
        • Safety Relays
        • Interface Terminal
        • Automotive Relays
    • Sensors
    • ENCODERS/POTENTIOMETERS
      • ENCODERS
      • ENCODERS
      • ROTARY POTENTIOMETERS
      • POSITION SENSOR
    • COOLING FAN
      • AXIAL TYPE
      • RADIAR TYPE
    • FA SENSORS & COMPONENTS
      • GENERAL-PURPOSE SENSORS
      • MEASUREMENT SENSORS
        • LASER DISPLACEMENT SENSOR
      • MOTORS FOR FA
        • MINAS A7 FAMILY
        • MINAS A6 FAMILY
      • PROGRAMMABLE CONTROLLERS
        • PROGRAMMABLE CONTROLLERS
      • HUMAN MACHINE INTERFACE
      • GENERAL-PURPOSE SENSORS
        • Photoelectric Sensors
        • LASER SENSORS
        • MICRO PHOTOELECTRIC SENSORS
        • AREA SENSORS
        • PRESSURE SENSORS
        • INDUCTIVE PROXIMITY SENSORS
        • PARTICULAR USE SENSORS
        • SENSOR OPTIONS
  • AECO
  • SAKAE
    • CONTACT TYPE
    • CONTACLESS TYPE
    • OIL FILLED TYPE
    • MULTI-TURN POTENTIOMETERS
      • CONTACT TYPE
      • Contactless type
      • Oil-Filled type
    • LINEAR-MOTION POT
      • CONTACT TYPE
      • CONTACLESS TYPE
      • OIL FILLED TYPE
      • RESISTIVE ELEMENT SUB-ASSEMBLY
    • SEESAW-MOTION POTENTIOMETERS UNIT
    • TURNS-COUNTING DIAL
    • JOYSTICK CONTROLLERS
  • Produk Lainnya
  • ASCO
  • azbil
  • BANNER
  • NIDEC
    • Pressure Sensor Modules
    • Potentiometers, Inclinometers
    • Rotary Encoders
  • BURKERT
    • Solenoid Valves
      • General Purpose 2/2 Solenoids

Testimonial

» lihat testimonial
» isi testimonial
  • 123

Featured

Mercotac M 110
Mercotac M 110
MULTIFEEDER BTSR
MULTIFEEDER BTSR
Magnetic Sensors
Magnetic Sensors
Photoelectric Sensors
Photoelectric Sensors
High Current SMT Power Inductor
High Current SMT Power Inductor
berhasil ditambahkan ke keranjang.

Soft starter

ABB Soft starter

Display :
  • «
  • 1
  • »
Sort By:
PSTX840-600-70

PSTX840-600-70

Model: PSTX840-600-70

Order No: 1SFA898219R7000

SKU: 10000006542601

Condition: New Sealed Under Guarantee

Size: 435.00 mm,493.00 mm,369.00 mm

Weight: 46.50KG

Brief Introduction

PSTX840-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 250 kW(400 V) 450 kW(500 V) 600 kW(690 V) 800 kWRated Operational Current - In-Line Connection (Ie):840 ARated Operational Power - Inside Delta Connection:at 230 V 450 kWat 400 V 800 kWat 500 V 1000 kWat 690 V 1400 kWRated Operational Current - Inside Delta Connection:1455 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 45 N·mProduct Main Type:PSTX840Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX720-600-70

PSTX720-600-70

Model: PSTX720-600-70

Order No: 1SFA898218R7000

SKU: 10000006542401

Condition: New Sealed Under Guarantee

Size: 435.00 mm,493.00 mm,369.00 mm

Weight: 46.50KG

Brief Introduction

PSTX720-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 200 kW(400 V) 400 kW(500 V) 500 kW(690 V) 710 kWRated Operational Current - In-Line Connection (Ie):720 ARated Operational Power - Inside Delta Connection:at 230 V 355 kWat 400 V 710 kWat 500 V 880 kWat 690 V 1200 kWRated Operational Current - Inside Delta Connection:1247 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 45 N·mProduct Main Type:PSTX720Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX570-600-70

PSTX570-600-70

Model: PSTX570-600-70

Order No: 1SFA898217R7000

SKU: 10000006542501

Condition: New Sealed Under Guarantee

Size: 361.00 mm,493.00 mm,282.00 mm

Weight: 27.00KG

Brief Introduction

PSTX570-600-70

Technical parametersRated Operating Voltage:208 ... 690 V ACRated control supply voltage (U.)s):100 ... 250 V ACRated control circuit voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operating Power - Coaxial Connection (PE):(230 V) 160 kW(400 V) 315 kW(500 V) 400 kW(690 V) 560 kWRated Operating Current - Coaxial Connection (IE):570 ARated Operating Power - Inner Delta Connection:at 230 V 295 kWat 400 V 540 kWat 500 V 700 kWat 690 V 960 kWRated Operating Current - Inner Delta Connection:987 APercentage of Safety Factor:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting capacity at maximum rated current Ie:4xIe for 10sSlope Time:1 ... 120 second [unit of time]Initial voltage at start-up:10 ... 99 %Special Buck Ramps:100 ... 10 %Inner triangle connection switch:beRunning Signal Relay:beBypass Signal Relay:YesFault Signal Relays:YesOverload Signal Relay:beReady to start/standby signal indication ON (LED):GreenOperational signal indication R (LED):GreenProtection Signal Indication (LED):YellowFault Signal Indication (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPIngress Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsControl circuit connection capacity:Rigid 1 x 2.5 mm²Power supply circuit connection capacity:Rigid 1 x 2.5 mm²Tightening torque:Main Circuit 35 N·mProduct range:PSTX570Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Functions:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX250-600-70

PSTX250-600-70

Model: PSTX250-600-70

Order No: 1SFA898213R7000

SKU: 10000006541901

Condition: New Sealed Under Guarantee

Size: 258.00 mm,470.00 mm,279.00 mm

Weight: 15.50KG

Brief Introduction

PSTX250-600-70

Technical parametersRated Operating Voltage:208 ... 690 V ACRated control supply voltage (U.)s):100 ... 250 V ACRated control circuit voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operating Power - Coaxial Connection (PE):(230 V) 75 kW(400 V) 132 kW(500 V) 160 kW(690 V) 220 kWRated Operating Current - Coaxial Connection (IE):250 ARated Operating Power - Inner Delta Connection:at 230 V 132 kWat 400 V 220 kWat 500 V 295 kWat 690 V 400 kWRated Operating Current - Inner Delta Connection:430 APercentage of Safety Factor:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting capacity at maximum rated current Ie:4xIe for 10sSlope Time:1 ... 120 second [unit of time]Initial voltage at start-up:10 ... 99 %Special Buck Ramps:100 ... 10 %Current Limiting Function:1.5 ... 7.5 xleInner triangle connection switch:beRunning Signal Relay:beBypass Signal Relay:YesFault Signal Relays:YesOverload Signal Relay:beAnalog Output:0… 10 V, 0... 20 mA, 4... 20 mAReady to start/standby signal indication ON (LED):GreenOperational signal indication R (LED):GreenProtection Signal Indication (LED):YellowFault Signal Indication (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPIngress Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsMain circuit connection capacity:Hole Diameter 8.5 mmControl circuit connection capacity:Rigid 1 x 2.5 mm²Power supply circuit connection capacity:Rigid 1 x 2.5 mm²Tightening torque:Main Circuit 25 N·mProduct range:PSTX250Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Functions:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX210-600-70

PSTX210-600-70

Model: PSTX210-600-70

Order No: 1SFA898212R7000

SKU: 10000006543601

Condition: New Sealed Under Guarantee

Size: 258.00 mm,470.00 mm,279.00 mm

Weight: 13.30KG

Brief Introduction

PSTX210-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 59 kW(400 V) 110 kW(500 V) 132 kW(690 V) 184 kWRated Operational Current - In-Line Connection (Ie):210 ARated Operational Power - Inside Delta Connection:at 230 V 102 kWat 400 V 184 kWat 500 V 250 kWat 690 V 315 kWRated Operational Current - Inside Delta Connection:360 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Main Circuit:Hole Diameter 10.2 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 25 N·mProduct Main Type:PSTX210Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX142-600-70

PSTX142-600-70

Model: PSTX142-600-70

Order No: 1SFA898210R7000

SKU: 10000006542701

Condition: New Sealed Under Guarantee

Size: 199.00 mm,377.00 mm,283.00 mm

Weight: 7.00KG

Brief Introduction

PSTX142-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 37 kW(400 V) 75 kW(500 V) 90 kW(690 V) 132 kWRated Operational Current - In-Line Connection (Ie):142 ARated Operational Power - Inside Delta Connection:at 230 V 75 kWat 400 V 132 kWat 500 V 160 kWat 690 V 220 kWRated Operational Current - Inside Delta Connection:245 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 14 N·mProduct Main Type:PSTX142Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX105-600-70

PSTX105-600-70

Model: PSTX105-600-70

Order No: 1SFA898209R7000

SKU: 10000006542001

Condition: New Sealed Under Guarantee

Size: 150.00 mm,314.00 mm,198.00 mm

Weight: 4.70KG

Brief Introduction

PSTX105-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 30 kW(400 V) 55 kW(500 V) 75 kW(690 V) 90 kWRated Operational Current - In-Line Connection (Ie):105 ARated Operational Power - Inside Delta Connection:at 230 V 55 kWat 400 V 90 kWat 500 V 110 kWat 690 V 160 kWRated Operational Current - Inside Delta Connection:181 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX105Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX85-600-70

PSTX85-600-70

Model: PSTX85-600-70

Order No: 1SFA898208R7000

SKU: 10000006542101

Condition: New Sealed Under Guarantee

Size: 150.00 mm,314.00 mm,198.00 mm

Weight: 4.70KG

Brief Introduction

PSTX85-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 22 kW(400 V) 45 kW(500 V) 55 kW(690 V) 75 kWRated Operational Current - In-Line Connection (Ie):85 ARated Operational Power - Inside Delta Connection:at 230 V 40 kWat 400 V 75 kWat 500 V 90 kWat 690 V 132 kWRated Operational Current - Inside Delta Connection:147 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX85Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX72-600-70

PSTX72-600-70

Model: PSTX72-600-70

Order No: 1SFA898207R7000

SKU: 10000006542201

Condition: New Sealed Under Guarantee

Size: 150.00 mm,314.00 mm,198.00 mm

Weight: 4.60KG

Brief Introduction

PSTX72-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 18.5 kW(400 V) 37 kW(500 V) 45 kW(690 V) 59 kWRated Operational Current - In-Line Connection (Ie):72 ARated Operational Power - Inside Delta Connection:at 230 V 37 kWat 400 V 59 kWat 500 V 80 kWat 690 V 110 kWRated Operational Current - Inside Delta Connection:124 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX72Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX60-600-70

PSTX60-600-70

Model: PSTX60-600-70

Order No: 1SFA898206R7000

SKU: 10000006542301

Condition: New Sealed Under Guarantee

Size: 150.00 mm,314.00 mm,198.00 mm

Weight: 4.60KG

Brief Introduction

PSTX60-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 15 kW(400 V) 30 kW(500 V) 37 kW(690 V) 55 kWRated Operational Current - In-Line Connection (Ie):60 ARated Operational Power - Inside Delta Connection:at 230 V 30 kWat 400 V 55 kWat 500 V 75 kWat 690 V 90 kWRated Operational Current - Inside Delta Connection:105 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0 ... 10 V, 0 ... 20 mA, 4 ... 20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX60Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX37-600-70

PSTX37-600-70

Model: PSTX37-600-70

Order No: 1SFA898204R7000

SKU: 10000006543501

Condition: New Sealed Under Guarantee

Size: 150.00 mm,314.00 mm,198.00 mm

Weight: 4.60KG

Brief Introduction

PSTX37-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 9 kW(400 V) 18.5 kW(500 V) 22 kW(690 V) 30 kWRated Operational Current - In-Line Connection (Ie):37 ARated Operational Power - Inside Delta Connection:at 230 V 15 kWat 400 V 30 kWat 500 V 37 kWat 690 V 55 kWRated Operational Current - Inside Delta Connection:64 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX37Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSTX30-600-70

PSTX30-600-70

Model: PSTX30-600-70

Order No: 1SFA898203R7000

SKU: 10000006543301

Condition: New Sealed Under Guarantee

Size: 150.00 mm,314.00 mm,198.00 mm

Weight: 4.60KG

Brief Introduction

PSTX30-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 7.5 kW(400 V) 15 kW(500 V) 18.5 kW(690 V) 25 kWRated Operational Current - In-Line Connection (Ie):30 ARated Operational Power - Inside Delta Connection:at 230 V 12.5 kWat 400 V 25 kWat 500 V 30 kWat 690 V 45 kWRated Operational Current - Inside Delta Connection:52 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX30Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Whatsapp
PSE105-600-70

PSE105-600-70

Model: PSE105-600-70

Order No: 1SFA897109R7000

SKU: 10000006544301

Condition: New Sealed Under Guarantee

Size: 90.00 mm,184.00 mm,245.00 mm

Weight: 2.90KG

Brief Introduction

PSE105-600-70

TechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 30 kW(400 V) 55 kW(500 V) 75 kWRated Operational Current - In-Line Connection (Ie):106 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE105Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection

Whatsapp
PSR72-600-70

PSR72-600-70

Model: PSR72-600-70

Order No: 1SFA896113R7000

SKU: 10000006617901

Condition: New Sealed Under Guarantee

Size: 180.00 mm,70.00 mm,220.00 mm

Weight: 2.10KG

Brief Introduction

PSR72-600-70

OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:Softstarter PSR60 ... PSR105 for 100 - 240VInstructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:180 mmProduct Net Height:220 mmProduct Net Depth / Length:70 mmProduct Net Weight:2.1 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 22 kW(400 V) 37 kW(500 V) 45 kWRated Operational Current - In-Line Connection (Ie):72 AService Factor Percentage:100 %Overload Protection:Recommended MS495 57 ... 75Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10Terminal Type:Main Circuit: BarsConnecting Capacity Main Circuit:Rigid 1x 10 ... 95 mm²Rigid 2 x 6 ... 35 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1 x 0.75 ... 2.5 mm²Rigid 2 x 0.75 ... 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 0.6 N·mMain Circuit 8 N·mSupply Circuit 0.6 N·mProduct Main Type:PSR72Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 20 Hp(220 ... 240 V AC) Three Phase 25 Hp(440 ... 480 V AC) Three Phase 50 Hp(550 ... 600 V AC) Three Phase 60 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 5.3 in·lbMain Circuit 70.8Supply Circuit 5.3 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR60-600-70,PSR72-600-70,PSR85-600-70,PSR105-600-70,PSRC60-600-70,PSRC72-600-70,PSRC85-600-70,PSRC105-600-70,PSR60-600-11,PSR72-600-11,PSR85-600-11,PSR105-600-11,PSRC60-600-11,PSRC72-600-11,PSRC85-600-11,PSRC105-600-11, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR60-600-70,PSR72-600-70,PSR85-600-70,PSR105-600-70,PSRC60-600-70,PSRC72-600-70,PSRC85-600-70,PSRC105-600-70,PSR60-600-11,PSR72-600-11,PSR85-600-11,PSR105-600-11,PSRC60-600-11,PSRC72-600-11,PSRC85-600-11,PSRC105-600-11, Made in ChinaDeclaration of Conformity - CE:1SFA1-95Container InformationPackage Level 1 Width:195 mmPackage Level 1 Depth / Length:86 mmPackage Level 1 Height:230 mmPackage Level 1 Gross Weight:2.3 kgPackage Level 1 EAN:7320500362617Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter

Whatsapp
PSR45-600-70

PSR45-600-70

Model: PSR45-600-70

Order No: 1SFA896111R7000

SKU: 10000007116001

Condition: New Sealed Under Guarantee

Size: 153.00 mm,54.00 mm,187.00 mm

Weight: 1.00KG

Brief Introduction

PSR45-600-70

OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:1SFC132032M0001Instructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:153 mmProduct Net Height:187 mmProduct Net Depth / Length:54 mmProduct Net Weight:1 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 11 kW(400 V) 22 kW(500 V) 30 kWRated Operational Current - In-Line Connection (Ie):45 AService Factor Percentage:100 %Overload Protection:Recommended MS450 36 ... 45Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Rigid 1x 6 ... 35 mm²Rigid 2 x 6 ... 16 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1 x 0.75 ... 2.5 mm²Rigid 2 x 0.75 ... 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 0.6 N·mMain Circuit 4 N·mSupply Circuit 0.6 N·mProduct Main Type:PSR45Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 15 Hp(220 ... 240 V AC) Three Phase 15 Hp(440 ... 480 V AC) Three Phase 30 Hp(550 ... 600 V AC) Three Phase 40 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 5.3 in·lbMain Circuit 35.4Supply Circuit 5.3 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR37-600-70, PSR45-600-70, PSRC37-600-70, PSRC45-600-70, PSR37-600-11, PSR45-600-11, PSRC37-600-11, PSRC45-600-11, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR37-600-70, PSR45-600-70, PSRC37-600-70, PSRC45-600-70, PSR37-600-11, PSR45-600-11, PSRC37-600-11, PSRC45-600-11, Made in ChinaDeclaration of Conformity - CE:1SFA1-91Container InformationPackage Level 1 Width:163 mmPackage Level 1 Depth / Length:56 mmPackage Level 1 Height:217 mmPackage Level 1 Gross Weight:1.1 kgPackage Level 1 EAN:7320500338346Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter

Whatsapp
PSR16-600-70

PSR16-600-70

Model: PSR16-600-70

Order No: 1SFA896107R7000

SKU: 10000007212301

Condition: New Sealed Under Guarantee

Size: 114.00 mm,45.00 mm,140.00 mm

Weight: 0.40KG

Brief Introduction

PSR16-600-70

OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:Softstarter PSR3 ... PSR16 for 100-240VInstructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:114 mmProduct Net Height:140 mmProduct Net Depth / Length:45 mmProduct Net Weight:0.4 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 4 kW(400 V) 7.5 kW(500 V) 7.5 kWRated Operational Current - In-Line Connection (Ie):16 AService Factor Percentage:100 %Overload Protection:Recommended MS132 10.00 ... 16.00Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:NoFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 1 N·mMain Circuit 1 N·mSupply Circuit 1 N·mProduct Main Type:PSR16Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 5 Hp(440 ... 480 V AC) Three Phase 10 Hp(550 ... 600 V AC) Three Phase 10 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 8.9 in·lbMain Circuit 8.9Supply Circuit 8.9 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CE:1SFA1-86Container InformationPackage Level 1 Width:121 mmPackage Level 1 Depth / Length:50 mmPackage Level 1 Height:156 mmPackage Level 1 Gross Weight:0.5 kgPackage Level 1 EAN:7320500338261Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter

Whatsapp
PSR12 600 70

PSR12 600 70

Model: PSR12 600 70

Order No: 1SFA896106R7000

SKU: 10000006702801

Condition: New Sealed Under Guarantee

Size: 114.00 mm,45.00 mm,140.00 mm

Weight: 0.40KG

Brief Introduction

PSR12 600 70

OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:Softstarter PSR3 ... PSR16 for 100-240VInstructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:114 mmProduct Net Height:140 mmProduct Net Depth / Length:45 mmProduct Net Weight:0.4 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 3 kW(400 V) 5.5 kW(500 V) 5.5 kWRated Operational Current - In-Line Connection (Ie):12 AService Factor Percentage:100 %Overload Protection:Recommended MS132 10.00 ... 16.00Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:NoFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 1 N·mMain Circuit 1 N·mSupply Circuit 1 N·mProduct Main Type:PSR12Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 3 Hp(440 ... 480 V AC) Three Phase 7.5 Hp(550 ... 600 V AC) Three Phase 10 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 8.9 in·lbMain Circuit 8.9Supply Circuit 8.9 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CE:1SFA1-86Container InformationPackage Level 1 Width:121 mmPackage Level 1 Depth / Length:50 mmPackage Level 1 Height:156 mmPackage Level 1 Gross Weight:0.5 kgPackage Level 1 EAN:7320500338247Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter

Whatsapp
PSE72-600-70

PSE72-600-70

Model: PSE72-600-70

Order No: 1SFA897107R7000

SKU: 10000006880801

Condition: New Sealed Under Guarantee

Size: 90.00 mm,184.00 mm,245.00 mm

Weight: 2.90KG

Brief Introduction

PSE72-600-70

TechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 18.5 kW(400 V) 37 kW(500 V) 45 kWRated Operational Current - In-Line Connection (Ie):72 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE72Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection

Whatsapp
PSE60-600-70

PSE60-600-70

Model: PSE60-600-70

Order No: 1SFA897106R7000

SKU: 10000006544201

Condition: New Sealed Under Guarantee

Size: 90.00 mm,184.00 mm,245.00 mm

Weight: 2.90KG

Brief Introduction

PSE60-600-70

TechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 15 kW(400 V) 30 kW(500 V) 37 kWRated Operational Current - In-Line Connection (Ie):60 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE60Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection

Whatsapp
PSE45-600-70

PSE45-600-70

Model: PSE45-600-70

Order No: 1SFA897105R7000

SKU: 10000006618001

Condition: New Sealed Under Guarantee

Size: 90.00 mm,184.00 mm,245.00 mm

Weight: 2.90KG

Brief Introduction

PSE45-600-70

Rated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 11 kW(400 V) 22 kW(500 V) 30 kWRated Operational Current - In-Line Connection (Ie):45 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE45Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection

Whatsapp
  • «
  • 1
  • »

Lihat Juga

MERCOTAC 830
MERCOTAC 830
PSENcode - non-contact, coded safety switches
PSENcode - non-contact, coded safety switches
E3AS-HL / F / L Series
E3AS-HL / F / L Series
Contactors, Overloads, and Breakers
Contactors, Overloads, and Breakers
High Current SMT Power Inductor
High Current SMT Power Inductor
Mitsubishi Power Supply Q61P
Mitsubishi Power Supply Q61P
GR18
GR18
MULTIFEEDER BTSR
MULTIFEEDER BTSR
Information
  • HOME
  • About Us
  • CONTACT US
  Customer Service
  •  081905075757
  •  021 38739028
  •  sales.ptbati@gmail.com
  Tentang Kami

pt bandar aneka teknik indonesia

PT. BANDAR ANEKA TEKNIK INDONESIA

Ruko Boston Square Blok RK-2 No.33
Kota Wisata
Ciangsana, Gunung Putri
Kab. Bogor, Jawa Barat

Top